Products - Conventional transformers    Products - HR equivalents

External protection

C4215

EI 42/14,8

External protection

4.0 VA - 40ºC/B

Logo CE

Simple primary

Dual secondary


C4215

Weight/unit:

180 gr

C4215

Weight/minibox (Units: 5)

900 gr

C4215

Weight/bigbox (Units: 48)

8640 gr

HR Ref. Primary Sec. Sec. In

Vo

(In=0)

External protection Fuse
P1 P2 S1 S2 Is1 Is2

Sec. (F)

S1|S2

Prim. (T)

115|220

C4215015 125 V 220 V 4.5 V 4.5 V 444.0 mA 444.0 mA 2x(5.85) V 2x(500.0) mA 63.0 mA
C4215001 125 V 220 V 6.0 V 6.0 V 333.0 mA 333.0 mA 2x(7.8) V 2x(400.0) mA 63.0 mA
C4215003 125 V 220 V 7.5 V 7.5 V 267.0 mA 267.0 mA 2x(9.75) V 2x(315.0) mA 63.0 mA
C4215005 125 V 220 V 9.0 V 9.0 V 222.0 mA 222.0 mA 2x(11.7) V 2x(250.0) mA 63.0 mA
C4215007 125 V 220 V 12.0 V 12.0 V 167.0 mA 167.0 mA 2x(15.6) V 2x(200.0) mA 63.0 mA
C4215009 125 V 220 V 15.0 V 15.0 V 133.0 mA 133.0 mA 2x(19.5) V 2x(160.0) mA 63.0 mA
C4215011 125 V 220 V 18.0 V 18.0 V 111.0 mA 111.0 mA 2x(23.4) V 2x(125.0) mA 63.0 mA
C4215013 125 V 220 V 24.0 V 24.0 V 83.0 mA 83.0 mA 2x(31.2) V 2x(100.0) mA 63.0 mA
C4215

Technical characteristics:

  • Designed and manufactured according regulations EN61558/6 UL1585/2
  • Double isolation copper wire
  • Two-chamber coil
  • Coated with dried oven varnish class H (180ºC)
  • Vacuum sealed
  • Safety transformer class II / Protection index IP00 (For all models with no load voltage lower than 50V according to EN61558, and to 30V according to UL1585)
  • Thermal class materials B (130ºC/266ºF) or F (155ºC/311ºF) optionally.
  • Ambient temperature of 40ºC/104ºF
  • Primary of 125V-220V
  • Configurations of single secondary, dual secondary and center tapped.
  • Isolation Prim./Sec. superior at 5 MOhm at 500 Vcc
  • Primary dielectric strength / superior secondary at 3 KV, 1min.