Products - Ensapsultated transformers    Products - HR equivalents

External protection

E3814

EI 38/13,6

External protection

4.0 VA - 40ºC/B

Logo CE

Simple primary

Center tapped secondary


E3814

Weight/unit:

150 gr

E3814

Weight/minibox (Units: 5)

750 gr

E3814

Weight/bigbox (Units: 80)

12000 gr

HR Ref. Primary Sec. Sec. In

Vo

(In=0)

External protection Fuse
P1 P2 S1 S2 Is1 Is2

Sec. (F)

S1|S2

Prim. (T)

P1

E3814035 230 V - 4.5 V 4.5 V 444.0 mA 444.0 mA 2x(6.3) V 2x(630.0) mA 32.0 mA
E3814021 230 V - 6.0 V 6.0 V 333.0 mA 333.0 mA 2x(8.4) V 2x(400.0) mA 32.0 mA
E3814023 230 V - 7.5 V 7.5 V 267.0 mA 267.0 mA 2x(10.5) V 2x(315.0) mA 32.0 mA
E3814025 230 V - 9.0 V 9.0 V 222.0 mA 222.0 mA 2x(12.6) V 2x(250.0) mA 32.0 mA
E3814027 230 V - 12.0 V 12.0 V 167.0 mA 167.0 mA 2x(16.8) V 2x(200.0) mA 32.0 mA
E3814029 230 V - 15.0 V 15.0 V 133.0 mA 133.0 mA 2x(21.0) V 2x(160.0) mA 32.0 mA
E3814031 230 V - 18.0 V 18.0 V 111.0 mA 111.0 mA 2x(25.2) V 2x(125.0) mA 32.0 mA
E3814033 230 V - 24.0 V 24.0 V 83.0 mA 83.0 mA 2x(33.6) V 2x(100.0) mA 32.0 mA
E3814

Technical characteristics:

  • Designed and manufactured according regulations EN61558 EN60590 EN60472 UL506 UL1585
  • Two-chamber coil
  • Vacuum sealed
  • Safety transformer class II / Protection index IP00 (For all models with no load voltage lower than 50V according to EN61558, and to 30V according to UL1585)
  • External protection with fuse (See suggested type at table)
  • Self-extinguishing plastic UL94-VO
  • Epoxy resin class F
  • Isolation: Prim./Sec. = 10 MOhm to 500 Vcc - Sec./Sec. = 2 MOhm to 500 Vcc
  • Dielectric strength Prim. / Sec. = 5 kV / 1min.
  • Secondary voltage tolerances 5%
  • Test at 100% of all electrical parameters in production
  • Reliability tests for production batch (life term)
  • Certificates of production test results (under request)
  • Certifications VDE, UL; others certifications under request: CSA, SEMKO