Products - Ensapsultated transformers Products - HR equivalents
Types and features | Series index | Technical information
|
HR Ref. | Primary | Sec. | Sec. In |
Vo (In=0) |
External protection Fuse | ||||
---|---|---|---|---|---|---|---|---|---|
P1 | P2 | S1 | S2 | Is1 | Is2 |
Sec. (F) S1 |
Prim. (T) P1 |
||
E3808164 | 115 V | - | 4.5 V | - | 400.0 mA | - | 6.3 V | 500.0 mA | 40.0 mA |
E3808150 | 115 V | - | 6.0 V | - | 300.0 mA | - | 8.4 V | 400.0 mA | 40.0 mA |
E3808152 | 115 V | - | 7.5 V | - | 240.0 mA | - | 10.5 V | 315.0 mA | 40.0 mA |
E3808154 | 115 V | - | 9.0 V | - | 200.0 mA | - | 12.6 V | 250.0 mA | 40.0 mA |
E3808156 | 115 V | - | 12.0 V | - | 150.0 mA | - | 16.8 V | 200.0 mA | 40.0 mA |
E3808158 | 115 V | - | 15.0 V | - | 120.0 mA | - | 21.0 V | 160.0 mA | 40.0 mA |
E3808160 | 115 V | - | 18.0 V | - | 100.0 mA | - | 25.2 V | 125.0 mA | 40.0 mA |
E3808162 | 115 V | - | 24.0 V | - | 75.0 mA | - | 33.6 V | 80.0 mA | 40.0 mA |
Technical characteristics:
- Designed and manufactured according regulations EN61558 EN60590 EN60472 UL506 UL1585
- Two-chamber coil
- Vacuum sealed
- Safety transformer class II / Protection index IP00 (For all models with no load voltage lower than 50V according to EN61558, and to 30V according to UL1585)
- External protection with fuse (See suggested type at table)
- Self-extinguishing plastic UL94-VO
- Epoxy resin class F
- Isolation: Prim./Sec. = 10 MOhm to 500 Vcc - Sec./Sec. = 2 MOhm to 500 Vcc
- Dielectric strength Prim. / Sec. = 5 kV / 1min.
- Secondary voltage tolerances 5%
- Test at 100% of all electrical parameters in production
- Reliability tests for production batch (life term)
- Certificates of production test results (under request)
- Certifications VDE, UL; others certifications under request: CSA, SEMKO