Products - Ensapsultated transformers    Products - HR equivalents

External protection

E5419

EI 54/18,8

External protection

13.0 VA - 70ºC/B

Logo CE

Simple primary

Dual secondary


E5419

Weight/unit:

420 gr

E5419

Weight/minibox (Units: 1)

420 gr

E5419

Weight/bigbox (Units: 27)

11340 gr

HR Ref. Primary Sec. Sec. In

Vo

(In=0)

External protection Fuse
P1 P2 S1 S2 Is1 Is2

Sec. (F)

S1|S2

Prim. (T)

P1

E5419065 230 V - 4.5 V 4.5 V 1444.0 mA 1444.0 mA 2x(5.6) V 2x(1600.0) mA 80.0 mA
E5419051 230 V - 6.0 V 6.0 V 1083.0 mA 1083.0 mA 2x(7.5) V 2x(1250.0) mA 80.0 mA
E5419053 230 V - 7.5 V 7.5 V 867.0 mA 867.0 mA 2x(9.3) V 2x(1000.0) mA 80.0 mA
E5419055 230 V - 9.0 V 9.0 V 722.0 mA 722.0 mA 2x(11.2) V 2x(800.0) mA 80.0 mA
E5419057 230 V - 12.0 V 12.0 V 542.0 mA 542.0 mA 2x(15.0) V 2x(630.0) mA 80.0 mA
E5419059 230 V - 15.0 V 15.0 V 433.0 mA 433.0 mA 2x(18.7) V 2x(500.0) mA 80.0 mA
E5419061 230 V - 18.0 V 18.0 V 361.0 mA 361.0 mA 2x(22.5) V 2x(400.0) mA 80.0 mA
E5419063 230 V - 24.0 V 24.0 V 271.0 mA 271.0 mA 2x(30.0) V 2x(315.0) mA 80.0 mA
E5419

Technical characteristics:

  • Designed and manufactured according regulations EN61558 EN60590 EN60472 UL506 UL1585
  • Two-chamber coil
  • Vacuum sealed
  • Safety transformer class II / Protection index IP00 (For all models with no load voltage lower than 50V according to EN61558, and to 30V according to UL1585)
  • External protection with fuse (See suggested type at table)
  • Self-extinguishing plastic UL94-VO
  • Epoxy resin class F
  • Isolation: Prim./Sec. = 10 MOhm to 500 Vcc - Sec./Sec. = 2 MOhm to 500 Vcc
  • Dielectric strength Prim. / Sec. = 5 kV / 1min.
  • Secondary voltage tolerances 5%
  • Test at 100% of all electrical parameters in production
  • Reliability tests for production batch (life term)
  • Certificates of production test results (under request)
  • Certifications VDE, UL; others certifications under request: CSA, SEMKO