Products - Ensapsultated transformers    Products - HR equivalents

Short-circuit proof

U3006

UI 30/5,5

Short-circuit proof

3.0 VA - 40ºC/B

Logo CE

Dual primary

Dual secondary


U3006

Weight/unit:

130 gr

U3006

Weight/minibox (Units: 5)

650 gr

U3006

Weight/bigbox (Units: 72)

9360 gr

HR Ref. Primary Sec. Sec. In

Vo

(In=0)

Sec. Prot.
P1 P2 S1 S2 Is1 Is2 CC (*)
U3006007 115 V 115 V 4.5 V 4.5 V 333.0 mA 333.0 mA 2x(7.6) V CC
U3006000 115 V 115 V 6.0 V 6.0 V 250.0 mA 250.0 mA 2x(10.2) V CC
U3006001 115 V 115 V 7.5 V 7.5 V 200.0 mA 200.0 mA 2x(12.7) V CC
U3006002 115 V 115 V 9.0 V 9.0 V 167.0 mA 167.0 mA 2x(15.3) V CC
U3006003 115 V 115 V 12.0 V 12.0 V 125.0 mA 125.0 mA 2x(20.4) V CC
U3006004 115 V 115 V 15.0 V 15.0 V 100.0 mA 100.0 mA 2x(25.5) V CC
U3006005 115 V 115 V 18.0 V 18.0 V 83.0 mA 83.0 mA 2x(30.6) V CC
U3006006 115 V 115 V 24.0 V 24.0 V 62.0 mA 62.0 mA 2x(40.8) V CC
U3006507 115 V 115 V 4.5 V 4.5 V 333.0 mA 333.0 mA 2x(7.6) V CC
U3006500 115 V 115 V 6.0 V 6.0 V 250.0 mA 250.0 mA 2x(10.2) V CC
U3006501 115 V 115 V 7.5 V 7.5 V 200.0 mA 200.0 mA 2x(12.7) V CC
U3006502 115 V 115 V 9.0 V 9.0 V 167.0 mA 167.0 mA 2x(15.3) V CC
U3006503 115 V 115 V 12.0 V 12.0 V 125.0 mA 125.0 mA 2x(20.4) V CC
U3006504 115 V 115 V 15.0 V 15.0 V 100.0 mA 100.0 mA 2x(25.5) V CC
U3006505 115 V 115 V 18.0 V 18.0 V 83.0 mA 83.0 mA 2x(30.6) V CC
U3006506 115 V 115 V 24.0 V 24.0 V 62.0 mA 62.0 mA 2x(40.8) V CC

(*) CC means short-circuit proof

U3006

(Vista lado terminales)

Technical characteristics:

  • Designed and manufactured according regulations EN61558 EN60590 EN60472 UL506 UL1585
  • Two-chamber coil
  • Vacuum sealed
  • Safety transformer class II / Protection index IP00 (For all models with no load voltage lower than 50V according to EN61558, and to 30V according to UL1585)
  • Short-circuit-protected
  • Self-extinguishing plastic UL94-VO
  • Epoxy resin class F
  • Isolation: Prim./Sec. = 10 MOhm to 500 Vcc - Sec./Sec. = 2 MOhm to 500 Vcc
  • Dielectric strength Prim. / Sec. = 5 kV / 1min.
  • Secondary voltage tolerances 5%
  • Test at 100% of all electrical parameters in production
  • Reliability tests for production batch (life term)
  • Certificates of production test results (under request)
  • Certifications VDE, UL; others certifications under request: CSA, SEMKO