Products - Toroidal transformers    Products - HR equivalents

Types and features | Series index
External protection

T100

T100

External protection

1000.0 VA - 40ºC/B

Logo CE

Acording regulations:

EN61558/6 UL1585/2

Simple primary(V):

230

Dual secondary(V):

2x( 30.0 / 35.0 / 40.0 / 50.0 / 55.0 / 60.0 / 80.0 )

Vo/Vn:

1.05 (Vo-no load voltage, Vn-load voltage)

T100

Weight/unit:

6920 gr

> Dual secondary

Dual secondary

T100
HR Ref. Power Ambient temperature

Ta

Primary Secondary
VA Vn Vn In

Vo

(In=0)

P1 P2 S1 S2 S1 S2
T100230 1000.0 VA 40/B 230 V - 30.0 V 30.0 V 16667.0 mA 16667.0 mA 2x31.5 V
T100235 1000.0 VA 40/B 230 V - 35.0 V 35.0 V 14286.0 mA 14286.0 mA 2x36.75 V
T100240 1000.0 VA 40/B 230 V - 40.0 V 40.0 V 12500.0 mA 12500.0 mA 2x42.0 V
T100250 1000.0 VA 40/B 230 V - 50.0 V 50.0 V 10000.0 mA 10000.0 mA 2x52.5 V
T100255 1000.0 VA 40/B 230 V - 55.0 V 55.0 V 9091.0 mA 9091.0 mA 2x57.75 V
T100260 1000.0 VA 40/B 230 V - 60.0 V 60.0 V 8333.0 mA 8333.0 mA 2x63.0 V
T100280 1000.0 VA 40/B 230 V - 80.0 V 80.0 V 6250.0 mA 6250.0 mA 2x84.0 V