Products - Conventional transformers    Products - HR equivalents

External protection

C6021

EI 60/21

External protection

18.0 VA - 40ºC/B

Logo CE

Simple primary

Center tapped secondary


C6021

Weight/unit:

515 gr

C6021

Weight/minibox (Units: 1)

515 gr

C6021

Weight/bigbox (Units: 18)

9270 gr

HR Ref. Primary Sec. Sec. In

Vo

(In=0)

External protection Fuse
P1 P2 S1 S2 Is1 Is2

Sec. (F)

S1|S2

Prim. (T)

115|220

C6021035 125 V 220 V 4.5 V 4.5 V 2000.0 mA 2000.0 mA 2x(5.4) V 2x(2500.0) mA 200.0 mA
C6021021 125 V 220 V 6.0 V 6.0 V 1500.0 mA 1500.0 mA 2x(7.2) V 2x(2000.0) mA 200.0 mA
C6021023 125 V 220 V 7.5 V 7.5 V 1200.0 mA 1200.0 mA 2x(9.0) V 2x(1250.0) mA 200.0 mA
C6021025 125 V 220 V 9.0 V 9.0 V 1000.0 mA 1000.0 mA 2x(10.8) V 2x(1250.0) mA 200.0 mA
C6021027 125 V 220 V 12.0 V 12.0 V 750.0 mA 750.0 mA 2x(14.4) V 2x(800.0) mA 200.0 mA
C6021029 125 V 220 V 15.0 V 15.0 V 600.0 mA 600.0 mA 2x(18.0) V 2x(630.0) mA 200.0 mA
C6021031 125 V 220 V 18.0 V 18.0 V 500.0 mA 500.0 mA 2x(21.6) V 2x(630.0) mA 200.0 mA
C6021033 125 V 220 V 24.0 V 24.0 V 375.0 mA 375.0 mA 2x(28.8) V 2x(400.0) mA 200.0 mA
C6021

Technical characteristics:

  • Designed and manufactured according regulations EN61558/6 UL1585/2
  • Double isolation copper wire
  • Two-chamber coil
  • Coated with dried oven varnish class H (180ºC)
  • Vacuum sealed
  • Safety transformer class II / Protection index IP00 (For all models with no load voltage lower than 50V according to EN61558, and to 30V according to UL1585)
  • Thermal class materials B (130ºC/266ºF) or F (155ºC/311ºF) optionally.
  • Ambient temperature of 40ºC/104ºF
  • Primary of 125V-220V
  • Configurations of single secondary, dual secondary and center tapped.
  • Isolation Prim./Sec. superior at 5 MOhm at 500 Vcc
  • Primary dielectric strength / superior secondary at 3 KV, 1min.