Products - Toroidal transformers    Products - HR equivalents

Types and features | Series index
External protection

T012

T012

External protection

120.0 VA - 40ºC/B

Logo CE

Simple primary

Dual secondary


T012

Weight/unit:

1370 gr

T012

Weight/minibox (Units: 1)

1370 gr

HR Ref. Primary Sec. Sec. In

Vo

(In=0)

External protection Fuse
P1 P2 S1 S2 Is1 Is2

Sec. (F)

S1|S2

Prim. (T)

P1

T012206 230 V - 6 V 6 V 10000 mA 10000 mA 2x(6) V 2x(12500) mA 1000 mA
T012210 230 V - 10 V 10 V 6000 mA 6000 mA 2x(11) V 2x(8000) mA 1000 mA
T012212 230 V - 12 V 12 V 5000 mA 5000 mA 2x(13) V 2x(6300) mA 1000 mA
T012215 230 V - 15 V 15 V 4000 mA 4000 mA 2x(16) V 2x(5000) mA 1000 mA
T012218 230 V - 18 V 18 V 3333 mA 3333 mA 2x(19) V 2x(4000) mA 1000 mA
T012222 230 V - 22 V 22 V 2727 mA 2727 mA 2x(24) V 2x(3150) mA 1000 mA
T012224 230 V - 24 V 24 V 2500 mA 2500 mA 2x(26) V 2x(3150) mA 1000 mA
T012230 230 V - 30 V 30 V 2000 mA 2000 mA 2x(33) V 2x(2500) mA 1000 mA
T012235 230 V - 35 V 35 V 1714 mA 1714 mA 2x(38) V 2x(2000) mA 1000 mA
T012240 230 V - 40 V 40 V 1500 mA 1500 mA 2x(44) V 2x(1600) mA 1000 mA
T012

Technical characteristics:

  • Designed and manufactured according regulations EN61558/6 UL1585/2
  • Double isolation copper wire
  • Two-chamber coil
  • Coated with dried oven varnish class H (180ºC)
  • Vacuum sealed
  • Safety transformer class II / Protection index IP00 (For all models with no load voltage lower than 50V according to EN61558, and to 30V according to UL1585)
  • Thermal class materials B (130ºC/266ºF) or F (155ºC/311ºF) optionally.
  • Ambient temperature of 40ºC/104ºF
  • Primary of 125V-220V
  • Configurations of single secondary, dual secondary and center tapped.
  • Isolation Prim./Sec. superior at 5 MOhm at 500 Vcc
  • Primary dielectric strength / superior secondary at 3 KV, 1min.