Products - Toroidal transformers Products - HR equivalents
Types and features | Series index
|
HR Ref. | Primary | Sec. | Sec. In |
Vo (In=0) |
External protection Fuse | ||||
---|---|---|---|---|---|---|---|---|---|
P1 | P2 | S1 | S2 | Is1 | Is2 |
Sec. (F) S1|S2 |
Prim. (T) P1 |
||
T075224 | 230 V | - | 24 V | 24 V | 15625 mA | 15625 mA | 2x(25) V | 2x(16000) mA | 6300 mA |
T075230 | 230 V | - | 30 V | 30 V | 12500 mA | 12500 mA | 2x(31) V | 2x(12500) mA | 6300 mA |
T075235 | 230 V | - | 35 V | 35 V | 10714 mA | 10714 mA | 2x(36) V | 2x(12500) mA | 6300 mA |
T075240 | 230 V | - | 40 V | 40 V | 9375 mA | 9375 mA | 2x(42) V | 2x(10000) mA | 6300 mA |
T075250 | 230 V | - | 50 V | 50 V | 7500 mA | 7500 mA | 2x(52) V | 2x(8000) mA | 6300 mA |
T075255 | 230 V | - | 55 V | 55 V | 6818 mA | 6818 mA | 2x(57) V | 2x(8000) mA | 6300 mA |
T075260 | 230 V | - | 60 V | 60 V | 6250 mA | 6250 mA | 2x(63) V | 2x(6300) mA | 6300 mA |
Technical characteristics:
- Designed and manufactured according regulations EN61558/6 UL1585/2
- Double isolation copper wire
- Two-chamber coil
- Coated with dried oven varnish class H (180ºC)
- Vacuum sealed
- Safety transformer class II / Protection index IP00 (For all models with no load voltage lower than 50V according to EN61558, and to 30V according to UL1585)
- Thermal class materials B (130ºC/266ºF) or F (155ºC/311ºF) optionally.
- Ambient temperature of 40ºC/104ºF
- Primary of 125V-220V
- Configurations of single secondary, dual secondary and center tapped.
- Isolation Prim./Sec. superior at 5 MOhm at 500 Vcc
- Primary dielectric strength / superior secondary at 3 KV, 1min.